Hydraulics

 

Qualification - Validation - Certification

 

Test Fluids

  • Water
  • Water-Glycol

 

Test types

  • Proof pressure
  • Burst
  • Pressure cycling
  • High-temperature creep testing
  • Extreme temperature cycling

 

Test samples

  • Gas storage cylinders
  • Vehicle gas storage systems
  • Valves, regulators, fittings and tubings
  • Relief devices (TPRD, burst discs, safety valves)
  • Sensors

 

Boundary conditions

  • Ambient and fluid temperature control: -40 °C to +85 °C
  • Pressure: up to 4500 bar
  • Cycling speed: up to 1 Hz

 

Pre-conditioning of test samples

  • Handling drop
  • Surface flaw
  • Pendulum impact and chemical exposure
  • Aged cyclinders